HardwareSpecifications
HardwareSpecifications | RG-CS85-24GT8XS-D | RG-CS85-24SFP/8GT8XS-D | RG-CS85-48GT4XS-D | RG-CS85-48GT4XS-HPD | RG-CS85-48SFP4XS-D |
InterfaceSpecifications | |||||
Fixed port | 24 x 10/100/1000 Mbps electrical ports with auto-negotiation, 8 x 1GE/10GE SFP+ ports | 24 x 1000 Mbps SFP ports (ports 1-16 are 100/1000 Mbps SFP ports), 8 x 10/100/1000 Mbps combo ports with auto-negotiation, 8 x 1GE/10GE SFP+ ports | 48 x 10/100/1000 Mbps electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports | 48 x 10/100/1000 Mbps electrical ports with auto-negotiation, PoE/PoE+ supported, 4 x 1GE/10GE SFP+ ports | 48 x 1000 Mbps SFP ports, 4 x 1GE/10GE SFP+ ports |
Fanmodule | 3fixed fans | 3fixed fans | 3fixed fans | 2 modular fans | 3 modular fans |
Power module | 2 replaceable hot-swappable power supply slots | 2 replaceable hot-swappable power supply slots | 2 replaceable hot-swappable power supply slots | 2 replaceable hot-swappable power supply slots | 2 replaceable hot-swappable power supply slots |
Fixed management port | 1 x console, 1 x MGMT, 1 x USB3.0 | 1 x console, 1 x MGMT, 1 x USB3.0 | 1 x console, 1 x MGMT, 1 x USB3.0 | 1 x console, 1 x MGMT, 1 x USB3.0 | 1 x console, 1 x MGMT, 1 x USB3.0 |
Expansion slot | One expansion slot | One expansion slot | One expansion slot | One expansion slot | One expansion slot |
SystemSpecifications | |||||
Packet forwarding rate | 512 Mpps | 512 Mpps | 488 Mpps | 488 Mpps | 488 Mpps |
Switching capacity | 688 Gbps | 688 Gbps | 656 Gbps | 656 Gbps | 656 Gbps |
MAC address table size | 64,000 | 64,000 | 64,000 | 64,000 | 64,000 |
ARP table size | 24,000 | 24,000 | 24,000 | 24,000 | 24,000 |
Number of IPv4 unicast routes | 24,000 | 24,000 | 24,000 | 24,000 | 24,000 |
Number of IPv4 multicast routes | 4,000 | 4,000 | 4,000 | 4,000 | 4,000 |
Number of IPv6 unicast routes | 14,000 | 14,000 | 14,000 | 14,000 | 14,000 |
Number of IPv6 multicast routes | 2,000 | 2,000 | 2,000 | 2,000 | 2,000 |
Number of ACEs | Ingress: 7,000 Egress:1,500 | ||||
Number of VSU members | 4 | 4 | 4 | 4 | 4 |
Dimensions and Weight | |||||
Dimensions (W x D x H) | 440 x 340 x 44 mm (17.32 x 13.39 x 1.73 in), 1 RU | 440 x 340 x 44 mm (17.32 x 13.39 x 1.73 in), 1 RU | 440 x 340 x 44 mm (17.32 x 13.39 x 1.73 in), 1 RU | 442 x 420 x 43.6 mm (17.40 x 16.54 x 1.72 in), 1 RU | 442 x 420 x 43.6 mm (17.40 x 16.54 x 1.72 in), 1 RU |
Weight | 4.4 kg (9.70 lbs) | 4.3 kg (9.48 lbs) | 4.5 kg (9.92 lbs) | 5.5 kg (12.12 lbs) | 5.3 kg (11.68 lbs) |
CPU and Storage | |||||
CPU | Dual-core CPU, 1.2 GHz | Dual-core CPU, 1.2 GHz | Dual-core CPU, 1.2 GHz | Dual-core CPU, 1.2 GHz | Dual-core CPU, 1.2 GHz |
Flash memory | 4 GB | 4 GB | 4 GB | 4 GB | 4 GB |
BootROM | 16 MB | 16 MB | 16 MB | 16 MB | 16 MB |
SDRAM | 1 GB | 1 GB | 1 GB | 1 GB | 1 GB |
Data packet buffer | 4 MB | ||||
Power and Consumption | |||||
Maximum power consumption | <60 W (excluding expansion modules) | <77 W (excluding expansion modules) | <70 W (excluding expansion modules) | <110 W (non-PoE) <1,590 W (PoE full load) | <150 W |
Maximum output power | RG-PA150IB-F:150 W | RG-PA150IB-F:150 W | RG-PA150IB-F:150 W | RG-PA600I-P-F: 600 W RG-PA1000I-P-F: 176 V AC to 290 V AC, 1000 W 90 V AC to 176 V AC, 930 W(PoE: 740 W) | RG-PA150IB-F: 150 W |
Rated input voltage | AC:100 V to 240 V HVDC: 240 V LVDC: 48 V to 60 V | AC: 200 V to 240 V DC: -48 V to -60 V | AC: 100 V to 240 V DC: -48 V to -60 V | ||
Maximum input voltage | AC:90 V to 264 V HVDC:192 V to 288 V LVDC:36 V to 75 V | AC:176 V to 264 V DC:-38 V to -75 V | AC:90 V to 264 V DC:-36 V to -75 V | ||
Environment and Reliability | |||||
MTBF | ≥ 1,051,000 hours | ≥ 823,000 hours | ≥ 963,000 hours | ≥ 832,000 hours | ≥ 788,000 hours |
Primary Airflow | Left-to-right and front-to-right airflow | Front-to-rear airflow | |||
Operating temperature | 0°C to 45°C (32°F to 113°F) | ||||
Storage temperature | -40°C to +70°C (-40°F to +158°F) | ||||
Operating humidity | 10% to 90% RH (non-condensing) | ||||
Storage humidity | 5% to 95% RH (non-condensing) | ||||
Operating noise | 45°C: 56.2 dB | 45°C: 57.1 dB | 45°C: 57.9 dB | 27°C: 50 dB 45°C: 65 dB | 27°C: 53 dB 45°C: 68 dB |
Interface surge protection | Power port: 6 kV/6 kV Telecom port: 10 kV (MGMT port: 4 kV) |
Software Specifications
RG-CS85Series | |
Feature | Description |
Ethernet switching | Jumbo frame (maximum length: 9,216bytes) |
IEEE 802.1Q (supporting 4K VLANs) | |
Voice VLAN | |
Super VLAN,Private VLAN | |
MAC VLAN,Port based VLAN,Protocol based VLAN,IP-Subnet based VLAN | |
GVRP | |
Basic QinQ Flexible QinQ | |
STP, RSTP, and MSTP | |
ERPS(G.8032) | |
LLDP/LLDP-MED | |
LACP (IEEE 802.3ad) | |
IP service | ARP |
DHCP client, DHCP relay, and DHCP server | |
DHCP snooping | |
DNS | |
DHCPv6 client and DHCPv6 relay | |
DHCPv6 snooping | |
Neighbor Discovery(ND) and ND snooping | |
IP routing | Static routing |
RIPand RIPng | |
OSPFv2, OSPFv3, IS-ISv4, ISv4, and IS-ISv6 | |
BGP4 and BGP4+ | |
IPv4and IPv6VRF | |
IPv4and IPv6PBR | |
Multicast | IGMP v1/v2/v3, and IGMP proxy |
IGMP v1/v2/v3 snooping | |
PIM-DM, PIM-SM, and PIM-SSM | |
MSDP | |
MLD v1/v2 | |
MLD snooping v1/v2 | |
PIM-SMv6 and PIM-SSM v6 | |
MPLS | MPLS L3VPN |
ACL and QoS | Standard IP ACLs Extended IP ACLs Extended MAC ACLs Time-based ACLs Expert-level ACLs ACL80 IPv6 ACL |
ACL redirection | |
Port traffic rate limiting | |
Congestion management:RR,SP,WRR,DRR,WFQ,SP+WRR, SP+DRR,and SP+WFQ | |
Congestion avoidance: tail drop, RED,and WRED | |
802.1p/DSCP/ToS traffic classification Eight priority queues per port | |
Security | Multiple AAAmodes |
RADIUS and TACAS+ | |
Port-based and MAC-based 802.1x authentication | |
Web authentication | |
HTTPS | |
SSHv1, SSHv2 | |
Global IP-MAC binding | |
Port isolation and port security | |
IP source guard | |
SAVI | |
CPP and NFPP | |
Strict and loose RPF uRPF ignoring default routes | |
Reliability | REUP, RLDP, DLDP |
IPv4 VRRP v2/v3 and IPv6 VRRP | |
BFD | |
Link tracing, fault notification, and remote loopback based on 802.3ah (EFM) | |
Hot swapping of power modules and cables | |
3-level fan speed adjustment Fan fault alarm | |
Device virtualization | Virtual Switching Unit (VSU) |
NMS and maintenance | SPAN,RSPAN,and ERSPAN |
sFLOW | |
NTPand SNTP | |
FTP and TFTP | |
SNMP v1/v2/v3 | |
RMON (1, 2, 3, 9) | |
NETCONF | |
CWMP (TR-069) standard protocol | |
gRPC | |
Cloudand SON | |
PoE | IEEE 802.3af and 802.3at Uninterruptible power supply upon hot start Port priority |